Regulation unit „RS 1“
The control unit RS 1 brings the temperature of the liquid in the primary circuit (boiler) to the desired set value of the secondary circuit (underfloor heating). The control station is modular and can easily be directly (by means of the pivoting 1” nipple) are connected to our distributors mounted on wall brackets. The versatility of this regulation is particularly evident in their use of systems, which are combined in high-temperature cycles (heating systems), with such a low temperature. This is a typical example of a housing unit with common bathrooms with underfloor heating and radiators (towel warmers, etc.) to create these systems are usually only on receipt of a transfer unit to be connected with appropriate heating circuits.
Operating principles:
The control unit provides for operating on the principle schematic hydraulic circuit, which has all the proper operation and easy maintenance necessary accessories. The key elements include:
1 Motor valve
2 Pump ball valve
3 Compensating Valve
4 Connection 1 "IG
5 blocking valve
6 differential bypass valve, adjustable between 0.2 and 0.6 bar
7 Automatic air vent valve
8 Fill- and drain valve
9 Eccentric-screw-joint for easy connection to the manifold
10 circulation pump
11 Thermometer
- max. Temp 90 ° C in the primary circuit
- max. static pressure of 10 bar
- Control range in the secondary circuit 20 - 60 ° C
- Differential bypass valve, adjustable range from 0.20 to 0.60 bar
- Thermometer m. Shank 3 / 8 ", 65mm diameter housing range 0 - 80 ° C
- Connections to the secondary distribution of rotating nipple with 1 "male nipple and soft seal
- Connections to the primary circuit (boiler) 1 "AG