Underfloor heating pipe
- Water-conducting inner pipe PE-RT (polyethylene raised-temperature) using up
to +95°C at 3.5 bar operating pressure
- Diffusion through two-layered sealing sheath made of special plastics;
TGM K test number 15718/1 - According to E-DIN 16833 / 16834 or DIN 4721, EN ISO 22391
- Is according to ÖNORM B 5159 and DIN 4726 at an oxygen diffusion current
of 0.10 gm-3, at 40°C, the tube refers to “oxygen tight” - Achieve a test value of the oxygen diffusion current of 0.039 gm-3, at 40°C. The tube as absolutely "oxygen tight" seen
Specifications:
- Field of Use: up to +95°C at 3.5
- Density: 0.936 g.m-3
- Tensile strength: 24 N/mm²
- Elongation at break: 770%
- Dielectric strength: up to -60°C.
- Modulus of elasticity: 710 mm²
- Bending radius: 20°C - 14 d
- High stabilized (oxidation – metal deactivation)
Security:
- Continuous load at 95°C and 3.5 bar
- Short-term temperature exposure of 110°C in the unfortunate occurrences have no negative impact on the utility value.
- High flexibility, therefore, to move without preheating.
- Welded (no mechanical coupling in the floor).
- Continuous quality control
Comfort:
- No cold feet because of the heat pad is where it should be, to the body and not on the ceiling.
- The heating system doesn’t disperse any dirt on a hot radiator.
- No irritation of the nasal mucous membranes, as higher relative humidity.
- No dirty wallpaper, curtains, carpets, etc.
Suitable for every floor covering
Now, even in residential areas attractive and easy-care ceramic floor coverings are used, because Multitherm-floor heating systems provide a high level of comfort.
Possible uses:
INTERIOR: homes, schools, churches, hospitals, restaurants, hotels, department stores, etc.
OUTSIDE: ramps, terraces, bridges, driveways, airport runs, collectors, etc.
MULTITHERM-PE-RT, like all the underfloor heating is not UV resistant.
OUTSIDE: ramps, terraces, bridges, driveways, airport runs, collectors, etc.
MULTITHERM-PE-RT, like all the underfloor heating is not UV resistant.